2X BMS Soft Parallel Connecting VIA P-LINK Module
Estimated reading time: 2 minutes
Partager
Quick answer: This guide documents a two-BMS soft parallel example using HC-function BMS boards and a P-LINK module. B/BD HC and HCRPB versions can use the matching P-LINK module; P-LINK is not limited to HCRPB and is not applicable to PB-series boards.
Before connecting: P-LINK soft parallel and the separate hard-parallel Parallel Module are different accessories. Confirm the exact board, module, cable and manual before wiring. The addresses and capacity values below belong to this test example, not universal settings or recommended pack capacities. A protocol appearing in an app menu does not by itself confirm inverter compatibility.
2X BMS SOFT PARALLEL CONNECTING VIA P-LINK
The accessories and connectings

1) bms settings from the settings page.
A).master bms setting addr to 0 as the pic.and the cap is 83.4AH.so from the master page,you can check the total cap as on pack.
B).slave bms setting addr to 1 as the pic.and the cap is 40AH.
C).You can also check the LCD from our testing,the total cap is 84.3AH.

D).You can also check our protocol build in the app.

this is the settings from the 2X bms with HC function and soft parallel connecting via P-link module.any questions and requests please feel free to contact us direclty as below:
📧 service@jkbms-ess.com 📱 WhatsApp: +1 818 938 3175 🌐 jkbms-ess.com
Related Technical Resources
Start with the JKBMS Technical Hub or the B/BD interface guide to identify the correct board and accessory interfaces. Use the BMS selection guide when comparing versions.
For PB boards, use the separate PB parallel-system example, not this P-LINK setup. Find exact-model manuals in the Download Center.
For questions about your own system, contact service@jkbms-ess.com, WhatsApp or the JKBMS Support Center with your exact BMS and module models.