JKBMS Inverter BMS (Home Energy Storage) Interface Guide
Estimated reading time: 5 minutes
Partager
Overview
This article provides a comprehensive interface definition for the JKBMS Inverter BMS series, designed for home energy storage (ESS) applications. It covers all physical ports, communication interfaces, and wiring definitions to help users correctly connect and operate the board.
Note: Interface availability may vary by model. Please refer to the port definition tables and diagrams below, and confirm against your specific model's user manual.
For related selection and compatibility guides, visit the JKBMS Technical Hub. Download the manual for your exact model from the Download Center, or submit a technical enquiry through the JKBMS Support Center.
Applicable Models
- JK-PBXA16SXP-V19
1. Board Layout & Interface Overview
The Inverter BMS features interfaces on both the front panel and the main board. Key areas include:
- Front Panel: RS485-1, RS485-2, CAN, One-Wire Port 3, RJ45 ports, DIP switches (ON/DP), dry contact terminals, ON/OFF button, RUN/ARM indicator LEDs, and temperature sensor inputs (L1–L6)
- Main Board (rear): Balance lead connectors (P1–P11), UART port, display board connector, heating interface (P10), battery negative terminal (B−), load output negative terminal (P−), battery positive terminal (BAT+/P11)
2. Front Panel Interfaces
RS485 Ports (RS485-1 & RS485-2)
Two independent RS485 communication ports via 8P8C (RJ45) connectors. Used for communication with inverters, monitoring systems, or multi-unit parallel networks.
PC host software connection for PB: Use an RS485-to-USB cable through the PB-series interface board. Connect to the appropriate RS485 port on that interface board, following the manual for your exact model. Do not use the PB UART or display connector for PC host software communication.
Firmware update tutorial: Read PB Series Firmware Upgrade: The Most Detailed Tutorial for illustrated PC software functions, CH340 driver installation, COM port selection, USB-RS485 connection to RS485-1 on the separate interface board, and firmware upgrade steps. V19.31 to V19.34 is the example, not the only upgrade path. Match the firmware to your exact model and hardware revision; never interchange V15 and V19 firmware.
- Protocol: Modbus RTU
- Connector: 8P8C RJ45
- Pin definition: refer to the RJ45 pin diagram (when connecting to BMS: RS485A, RS485B; when connecting to CAN: NC, NC, CANL, CANH, GND, NC)
CAN Port
CAN bus interface via RJ45 connector for communication with compatible inverters and ESS controllers.
- Default baud rate: 500 kbps (configurable)
- Supports mainstream ESS CAN protocols (e.g., Pylontech, SMA, Victron)
- Connector: 8P8C RJ45
One-Wire Port (6P6C RJ11)
One-Wire communication interface via 6P6C (RJ11) connector.
DIP Switches (ON / DP)
4-position DIP switch bank for address setting and function configuration. Refer to the user manual for switch position definitions.
Dry Contact Terminals
4-terminal dry contact (relay output) interface for alarm or external control signals.
ON/OFF Button
Main power on/off control for the BMS.
Temperature Sensor Inputs (L1–L6)
Up to 6 external NTC temperature sensor inputs for monitoring battery pack and environment temperatures.
3. Main Board Interfaces
D1 — Balance Lead Connector (P1)
Main balance lead input connector (24-pin). Connects to individual cell balance leads in strict cell order.
P2 / P3 — Display Board & Auxiliary Connectors
Connectors for the display board and auxiliary functions.
UART Port & Display Interface
On the PB series, both the UART port and the display interface are located on the BMS protection board (main board), not on the separate interface board. Both connect to the compatible PB display. They provide the same display connection function; the connector types differ. The display itself has two corresponding connection interfaces. Use the matching connector and cable for your board and display, and follow the model-specific manual.
These are display connections, not the PC host software connection. For PB PC communication, use an RS485-to-USB cable through the PB interface board's RS485 port. Do not substitute the USB-TTL connection method used with the GPS port on B/BD boards.
P4 / P5 — Auxiliary Connectors
Additional multi-pin connectors for extended functions (refer to pin definition table below).
P6–P9 — NTC Temperature Sensor Connectors
Multiple NTC temperature sensor connectors for cell-level temperature monitoring.
- Sensor type: NTC 10kΩ (at 25°C)
P10 — Heating Interface
2-pin connector for external heating pad control. Automatically activates in low-temperature conditions to protect cells during charging.
P11 / BAT+ — 16S Battery Positive Terminal
Battery pack total positive terminal connection point.
B− — Battery Total Negative Terminal
Battery pack total negative terminal.
P− — Load Output Negative Terminal
Negative output terminal for load / inverter connection.
4. Connector Pin Definitions
D1 (P1) — Balance Lead & Communication Connector
24-pin connector including: RUN-LED, ARM-LED, LED3–LED6, RS485-A1, RS485-A2, CANH1, GND, ADDR0–ADDR3, RS485-B1, CANL, INST+, INST−, and related signals. Refer to the pin diagram image below.
P2 — RS232 / RS485 Connector
Includes: RS232-TX/NC, RS232-RX/NC, GND1, GND1, RS485-B2, RS485-A2, NC.
P3 — Multi-function Connector
Includes: RS485-B2, GND0, NC, ON/OFF-LED, LED5, LED6, COM2, COM1, S2, S1, GND0.
5. Interface Comparison Summary
| Interface / Feature | Inverter BMS (JK-PB Series) |
|---|---|
| Bluetooth | ✅ |
| UART / display interface | Display connection; not for PC host software |
| PC host software connection | RS485-to-USB via the PB interface board |
| CAN (RJ45) | ✅ |
| RS485 × 2 (RJ45) | ✅ |
| One-Wire (RJ11) | ✅ |
| Heating Control | ✅ |
| NTC Temperature Sensors | ✅ (up to 6 channels) |
| Dry Contact Output | ✅ |
| DIP Address Switch | ✅ |
| Balance Leads | ✅ |
6. Safety Notes
- Always disconnect all power sources before wiring to avoid short circuits or electric shock.
- Do not hot-plug RS485, CAN, or UART interfaces.
- Balance leads must be connected in strict cell sequence — incorrect wiring may permanently damage the BMS.
- Confirm RJ45 pin definitions before connecting — RS485 and CAN share the same RJ45 form factor but have different pin assignments.
- If in doubt, contact JKBMS technical support or refer to the user manual for your specific model.
7. Board Photos & Wiring Reference
The photos below distinguish the PB interface board from the PB V19 BMS protection board. They are board-identification references, not complete pinout diagrams. For detailed connector pin definitions, refer to the manual for your exact model.

Figure 1. PB interface board. PB PC host software communication uses an RS485-to-USB cable connected through this board's RS485 port.

Figure 2. PB V19 BMS protection board (main board). Both the UART port and the display interface are on this board; they connect to the compatible PB display and differ in connector type.

1 commentaire
1. Label the connectors on the mainboard which are not identified on the mainboard. P4 – P11
2. Explain the purpose of P5. The wake and sleep switch is not mentioned anywhere in the manual