JKBMS JK-B2A8S30PS Series-Connection Smart BMS

Build compatible series-connected battery systems with the PS version, rather than treating a standard P board as a series-capable replacement. JK-B2A8S30PS manages a 3S–8S LiFePO4 or Li-ion pack, or a 7S–8S LTO pack, with up to 300A charging and discharging and 2A energy-transfer active balancing.

Series Connection: The PS Difference

The manual specifies a 100V series withstand rating and up to six 12V battery packs or three 24V battery packs connected in series. Each BMS still operates within its own 7.5–36V supply range. These are separate limits: do not connect a single board across a 100V battery pack. Confirm actual fully charged system voltage, pack compatibility and the complete system design before installation. Series connection does not multiply the current rating.

This PS series-connection version does not support heating. Heating descriptions and H-suffix options in the linked manual do not apply to the PS product supplied here.

Key Specifications

Parameter Specification
Model JK-B2A8S30PS
Version V19.0.1
Cell configuration per battery pack 3S–8S LiFePO4 / Li-ion; 7S–8S LTO
Supply voltage per BMS 7.5–36V
Maximum charging current 300A
Maximum discharging current 300A
Maximum instantaneous current 600A (duration not specified; not a continuous rating)
Maximum active balancing current 2A
Series withstand voltage 100V (not the single-pack supply-voltage range)
Maximum series-connected packs stated in manual 6 × 12V packs or 3 × 24V packs
Operating power consumption ≤1400mW
Operating temperature −30°C to +70°C
Maximum loop resistance 0.25mΩ
Board dimensions 182.75 × 127.26 × 15.6 mm
Finished board weight 541g
Temperature sensors 1 internal + 2 external; 4 external optional
Standard interfaces Bluetooth, UART/GPS interface, separate RS485 display interface
Heating Not supported

Monitoring, Balancing and Protection

Use the JKBMS Bluetooth app on Android or iOS to view battery data, configure supported parameters and control charging and discharging. Active balancing transfers energy from higher-voltage cells to lower-voltage cells when the configured conditions are met. The manual specifies ±3mV voltage acquisition accuracy, capacity calculation, logging and intelligent sleep.

Protection functions include cell overvoltage and undervoltage, charge and discharge overcurrent, short circuit, charge and discharge overtemperature, and low-temperature charging protection. Configure limits for the actual cells and system; factory defaults are not a universal charging recommendation.

Interfaces and Custom Communication Versions

This listing is for the base JK-B2A8S30PS: Bluetooth and UART are standard. The display connector carries RS485 signals and is separate from the UART/GPS connector. Use a compatible RS485 display and the correct harness; do not interchange UART and RS485 wiring.

Non-heating communication versions described in the manual: JK-B2A8S30PCS, JK-B2A8S30PRS, JK-B2A8S30PCRS. C denotes CAN and R denotes RS485. These are separate custom configurations, not communication features included with this base model. Confirm the protocol and connected equipment before ordering a custom configuration.

The manual also describes parallel operation with a separate matching parallel module. ACC and charger-detection functions are optional. External GPS equipment, display, alarm devices and parallel modules are not assumed to be included. Series support does not establish compatibility for shared communication wiring between series-connected packs; obtain a confirmed system wiring plan.

Installation and Setup

Follow the model-specific wiring diagrams and connector definitions in the manual. Verify the cell-tap sequence, B− and P− connections and mounting before power-up. The manual describes charger activation and activation through a compatible button or display. Set the cell chemistry, cell count, capacity and protection limits in the app before use. Keep conductors, connectors, fusing and thermal design appropriate for the actual load.

Manuals and Support

Download PS Series User Manual V19.0.1