BMS Connecting & Function Explanation for JK-B JK-BD Series BMS.
Estimated reading time: 4 minutes
Teilen
Parallel Model Connecting
The diagram below illustrates a B/BD hardware-parallel example using the separate Parallel Module. Use that module only with a board that has the corresponding Parallel Module Interface, and follow the exact board and module instructions. Do not apply the drawing as universal wiring instructions for all JKBMS versions.
For soft parallel connection, B/BD HC and HCRPB versions can use the matching P-LINK module. P-LINK is a different accessory from the hard-parallel Parallel Module and is not applicable to PB boards.
Two-BMS soft parallel example using P-LINK
------------------------------------------------------------------------------------------------

Diagram scope: Connector names and signal labels below refer to this reference drawing. Confirm the actual board revision, connector orientation and pin numbering in your model-specific manual before wiring. Interface availability varies by model and version.
Port Interface Definition
① T Sensor Port (HY2.0-4P)
This is a temperature-sensor connection, not a heating-film power connection. The reference drawing contains inconsistent sensor numbering; confirm the sensor assignments in the exact-model manual instead of interpreting them as a universal pinout.
② Alarm / Buzzer Port (A12534WF-2A)
Used to connect an external alarm or buzzer for fault notification on supported models. The drawing labels:
- GND: Alarm power −
- VCC: Alarm power +
③ Parallel Port (A1254WF-3A)
The drawing shows the control connection for the separate Parallel Module, sold separately. Use it only when your board has the matching Parallel Module Interface.
- P-status: Parallel module status signal
- P-EN: Parallel enable control signal
- GND: Signal GND
④ Display Port (A1254WF-6A)
Use a B/BD-compatible RS485 display, such as LCD-4.3-RS485. PB TTL-P displays are not interchangeable with B/BD displays. The reference drawing labels:
- K−: Active signal −
- K+: Active signal +
- GND: Power −
- B: LCD RS485 signal −
- A: LCD RS485 signal +
- VCC: LCD power out
⑤ ACC Test Port (A12534WF-5A)
The reference drawing shows charger-detection and ACC signals. Confirm availability and electrical requirements for the exact board before connecting external signals.
- C_Detect−: Charger output 12V −, as labeled in the reference drawing
- C_Detect+: Charger output 12V +, as labeled in the reference drawing
- NC: No connect
- ACC−: ACC −
- ACC+: ACC +
BMS Interface Definition
① CAN/485 Interface (A1254WF-4A)
The drawing shows a connector labeled for CAN and RS485 signals. In the Standard/HC/HCRPB comparison below, HC includes CAN, while HCRPB includes CAN and RS485. Do not assume that the combined connector drawing means HC has RS485.
- CAN_L: CAN signal −
- CAN_H: CAN signal +
- RS485_A: RS485 signal +
- RS485_B: RS485 signal −
Inverter or third-party monitoring compatibility requires the exact BMS model, firmware, protocol, adapter and cable pinout to match the other device's documentation. This drawing does not verify Solar Assistant support.
② GPS Interface (1.25T-4PWT)
For B/BD PC-software communication, use the appropriate USB-TTL cable at the protection board's GPS port. The B/BD RS485 display connection is a separate function. Do not use a PB USB-RS485 PC cable as a substitute.
- GND: Power / signal GND, as labeled in the drawing
- RX: UART_RX 3.3V, as labeled in the drawing
- TX: UART_TX 3.3V, as labeled in the drawing
- VGPS: Power output shown as approximately B+ in the drawing; verify the actual voltage before connecting an adapter
Important: Do not infer adapter power wiring from a connector label alone. Follow the exact board and cable documentation. Solar Assistant connectivity is a separate question and must be checked against its current model-specific instructions.
Additional Hardware
- Heating Film: On a supported model, connect a compatible heating film only to the heating connection specified in the exact-model manual. Do not connect heating-film power to the T Sensor port. The reference drawing separately identifies heating-film and temperature-sensor connections.
- T Sensor: Use the specified temperature sensor and sensor connection for your exact model.
- Battery Total + (P+): Main positive terminal of the battery pack, as labeled in the reference drawing.
- Parallel Module: Separate hardware-parallel accessory requiring the corresponding board interface. Sold separately; not the same accessory as P-LINK.
Version Comparison
This comparison covers the Standard, HC and HCRPB versions discussed here, not every JKBMS suffix or board revision. Check your exact SKU before ordering accessories.
| Feature | Standard | HC | HCRPB |
|---|---|---|---|
| Bluetooth | ✅ | ✅ | ✅ |
| UART | ✅ | ✅ | ✅ |
| CAN | ❌ | ✅ | ✅ |
| RS485 | ❌ | ❌ | ✅ |
| Heating | ❌ | ✅ | ✅ |
| Buzzer / Alarm | ❌ | ❌ | ✅ |
| Soft Parallel (P-LINK Module) | ❌ | ✅ | ✅ |
| Parallel Module Interface | ❌ | ❌ | ✅ |
Related Technical Resources
Use the JKBMS Technical Hub, B/BD interface guide and B/BD display guide for related model-selection information.
Download the manual for your exact board from the Download Center. For uncertain wiring or hardware identification, use the JKBMS Support Center or email service@jkbms-ess.com before connecting power.